What Is UVB?
The UVB test is an accelerated ageing test that represents the short-wavelength region of the solar spectrum using UVB-313 fluorescent lamps. It is more aggressive than UVA.
Purpose of UVB
The purpose is to screen materials' UV resistance quickly and to make fast comparisons between formulations.
Which Products Is UVB Applied To?
- Paint and coating formulations
- Plastic raw material trials
- Additive comparisons
In Which Sectors Is UVB Used?
Standards Related to UVB
- ISO 4892-3
- ASTM G154fluorescent UV accelerated aging test
- ISO 16474-3
UVB Conditions
- Lamba
- UVB-313
- Radiation
- Standard defined intensity in the 313 nm region
- Cycle
- Defined duration of light and condensation phases
- Black panel temperature
- Defined in standard
Equipment for UVB
- Fluorescent UV chamber (with UVB-313 lamps)
- Calibrated radiometer
- Colour and gloss meter
Sample Requirements for UVB
- Initial measurements must be taken
- A reference sample must be kept
- Generally at least three specimens
Duration of UVB
Because of the aggressiveness, durations are shorter; typically 100 – 500 hours.
UVB Procedure
- 1Initial measurements are taken.
- 2The UVB-313 lamp and irradiance setting are verified.
- 3Samples are placed on the panels.
- 4Cycles are run for the defined duration.
- 5Final measurements are taken and evaluated.
UVB Acceptance Criteria
The acceptance criterion is given in the specification as maximum colour difference and gloss loss.
Evaluation of Results
Because the UVB wavelength is present only minimally in the solar spectrum, it can produce unrealistic degradation mechanisms. Results therefore do not translate directly to field behaviour.
UVB Report
- Applied standard and lamp type
- Irradiance and cycle programme
- Exposure duration
- Colour difference and gloss values
Accreditation
EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.
Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.
Scope and authorisationsRelated Regulations
- Material development specifications
Environmental and Climatic Testing — What Does This Testing Field Cover?
The section below describes the field that the UVB test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.
Environmental testing shows whether a product withstands ambient factors such as temperature, humidity, pressure, solar radiation, dust, water and corrosive atmospheres. The aim is not to break the product but to bring forward, in ACCELERATED form, the conditions it will meet over its life.
Test profiles are derived from the product's real exposure, and that derivation is the actual engineering work of the field. A device operating in an enclosed office and one mounted on a pole are not tested with the same profile. The IEC 60068 series defines general methods, MIL-STD-810 military profiles, RTCA DO-160 aviation profiles and the ISO 16750 series location-based automotive profiles. A test applied without a profile selection produces both unnecessary cost and false confidence.
Temperature tests simulate three separate phenomena and all three produce different failure modes. Steady high/low temperature tests whether the material can operate at that temperature. Temperature CYCLING creates fatigue at joints between materials with different expansion coefficients — solder cracks appear here. Thermal SHOCK intensifies this effect through an abrupt transition.
There is a distinction in humidity testing too. Steady damp heat shows the diffusion of moisture into the material and its effect on insulation properties. Cyclic damp heat creates condensation: water droplets form on the cooling surface, and this is far more aggressive than dry humidity. Water ingress into enclosures, increased leakage current and corrosion usually appear in the cyclic test.
Dust and water protection is a separate body of work and is expressed by the IP code. The point to note here is that an IP test is not a DURABILITY test: it shows that protection is provided under defined and short-duration conditions, not resistance to long-term immersion or pressure washing.
The most common mistake in this family is translating a test result directly into a LIFE PREDICTION. Accelerated tests are designed for comparison and design verification; a reliable conversion between hours in a chamber and years in the field can only be established with a material-specific acceleration model calibrated against field data.
Functional monitoring determines the value of the test. Keeping a product in a temperature chamber and then switching it on does not show what happened DURING the test. In critical applications the product is operated throughout the test and its parameters are monitored; intermittent faults that appear and disappear can only be caught this way.
Method groups in this field
Temperature
Dry heat, cold, change of temperature and thermal shock; steady and cyclic profiles.
Humidity
Steady damp heat and cyclic damp heat; cycles with condensation are more aggressive.
Water and dust
IP protection tests: dripping, spraying, jets, immersion and dust tightness.
Radiation and ageing
Accelerated ageing by xenon arc and fluorescent UV, solar radiation simulation.
Pressure and altitude
Low pressure (altitude) and rapid pressure change tests.
Corrosive atmosphere
Salt spray, mixed flowing gas corrosion (simulating industrial atmospheres), mould and fungus tests.
Commonly confused in this field
- Test duration cannot be converted into field life; a conversion made without an acceleration model is misleading.
- Temperature cycling and steady temperature produce different failure modes; neither replaces the other.
- If the product is not operated during the test, intermittent faults remain invisible; functional monitoring determines the value of the test.
- IP protection is not evidence of durability; it shows protection under defined and short-duration conditions.
- A test applied without profile selection both increases cost and gives false confidence.
- The mounting and orientation arrangement affects the result; the report must document it.
Which decisions these results support
- Design verification and qualification
- Declaration of the protection class and operating temperature range
- Reproducing field failures in the laboratory and root cause analysis
- Supplier component approval
- Decisions on warranty period and storage conditions
Related Tests
Frequently Asked Questions About UVB
Do UVB results predict field life?
No. The UVB-313 lamp also includes short wavelengths not naturally present in sunlight, so it is suitable for fast screening and ranking, but not for predicting field life.