What Is NB-IoT — RED?
NB-IoT testing is a set of experiments in which the device using narrowband IoT technology defined by 3GPP is measured in terms of transmitter and receiver requirements, coverage extension (CE) levels and power saving behavior.
Purpose of NB-IoT — RED
The goal is to verify that the narrowband IoT device meets the network requirements under low data rate and deep coverage conditions.
Which Products Is NB-IoT — RED Applied To?
- Water, gas and electricity meters
- Indoor and basement sensors
- Parking and waste management sensors
- Long-lasting battery-powered monitoring devices
In Which Sectors Is NB-IoT — RED Used?
Standards Related to NB-IoT — RED
- REDEU radio equipment directive test
- ETSIEuropean telecommunications standards test
- FCCUS radio and EMC regulations test
NB-IoT — RED Conditions
- bandwidth
- Narrowband carrier; Defined in 3GPP
- Transmitter measurements
- Maximum output power, power control, spectrum emission mask, unwanted broadcasts
- Receiver measurements
- Reference sensitivity; at coverage expansion levels
- power saving
- Verifying PSM and eDRX modes
Equipment for NB-IoT — RED
- Cellular network emulator (NB-IoT supported)
- Wired RF test setup
- High resolution current measurement system
- protocol analyzer
Sample Requirements for NB-IoT — RED
- The device must support test SIM and test mode
- Declared bands and operating modes must be documented
- Coverage expansion levels must be configurable
- Final production software must be used
Duration of NB-IoT — RED
2–5 weeks depending on the number of tapes.
NB-IoT — RED Procedure
- 1The band and mode list is declared.
- 2Transmitter measurements are made.
- 3Receiver sensitivity is measured at coverage expansion levels.
- 4Power saving modes are verified.
- 5Unwanted publications are scanned.
- 6Results are compared with the limits.
NB-IoT — RED Acceptance Criteria
Acceptance criteria are the limit values given in 3GPP specifications.
Evaluation of Results
NB-IoT's long battery life claim depends largely on the correct configuration of power saving modes; A device that exceeds radio compliance may not provide the expected life in the field due to incorrect configuration.
NB-IoT — RED Report
- Declared bands and modes
- Applied specification versions
- Donor and receiver results
- Coverage expansion level results
- Current profile and power saving verification
Accreditation
EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.
Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.
Scope and authorisationsRelated Regulations
- Radio Equipment Directive 2014/53/EU (RED)
- Operator acceptance programs
RF and Wireless Testing — What Does This Testing Field Cover?
The section below describes the field that the NB-IoT test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.
RF and wireless testing shows that a device containing a radio uses the spectrum correctly and operates within the limits the relevant legislation allows. This family is a separate body of work from EMC: EMC addresses unwanted interference, whereas here INTENTIONAL emission is assessed.
Spectrum is a public and limited resource, and this determines the legal character of the field. A device spilling outside its permitted band or emitting excess power is not merely a technical defect but a violation that disrupts someone else's service. Radio conformity is therefore policed more strictly than other test fields and markets maintain their own national regimes.
Measurements run separately on the transmitter and receiver sides. On the transmitter side, output power, occupied bandwidth, frequency error, unwanted emissions, adjacent channel power and the power envelope are measured. On the receiver side, sensitivity, selectivity, blocking and spurious response rejection are assessed. The receiver side is often neglected, but in some bands it is a regulatory requirement.
Access protocol specific behaviours are a third axis: listen before talk (LBT), duty cycle, dynamic frequency selection (DFS) and transmit power control (TPC). These mechanisms enable spectrum sharing and it must be shown that they work correctly.
HUMAN EXPOSURE is the fourth axis and one of the most commercially critical. For devices used close to the body, SAR (specific absorption rate) is measured; for devices used at a distance, a field strength assessment is made. Limits and measurement methods vary by market; the same device is assessed separately for Europe and the United States.
Market regimes are decisive in this family and do not substitute for one another: the Radio Equipment Directive and ETSI harmonised standards in Europe, FCC authorisation in the United States (through a TCB for intentional radiators), ISED in Canada, MIC in Japan, KC in South Korea and SRRC in China each carry their own set of requirements. The same device requires a separate file for each market, and some markets impose a local representative or local testing requirement.
Module integration is the subject that raises the most questions in the field. Using a certified radio module does not automatically make the device compliant. A module certificate is valid for a defined antenna, a defined supply and defined conditions of use; if the antenna changes, the layout changes or the module is operated at a different power level, reassessment is required.
The presence of several radios in the same device (Wi-Fi + Bluetooth + cellular + NFC) gives rise to a simultaneous transmission assessment: SAR and unwanted emission measurements are made for the worst case in which the radios operate together.
Method groups in this field
Transmitter measurements
Output power, occupied bandwidth, frequency error, unwanted emissions, adjacent channel power, power spectral density.
Receiver measurements
Sensitivity, selectivity, blocking, spurious response rejection.
Spectrum sharing mechanisms
Verification of listen before talk, duty cycle, dynamic frequency selection and transmit power control.
Human exposure
SAR measurement (handheld and body-worn devices), field strength assessment, multi-radio scenarios.
Protocol conformity
Cellular network conformity testing, Bluetooth and Wi-Fi certification testing, GNSS performance.
Antenna measurements
Gain, radiation pattern, efficiency and total radiated power (TRP) measurements.
Commonly confused in this field
- Using a certified module does not automatically make the device compliant; if the antenna, layout or power level changes, reassessment is required.
- An FCC file does not replace a CE file; each market operates its own regime.
- Receiver side measurements are a regulatory requirement in some bands; measuring only the transmitter produces an incomplete file.
- SAR limits and measurement methods differ by market; a result in one market does not carry over to another.
- For devices carrying several radios the simultaneous transmission scenario must be assessed; measuring them individually is not sufficient.
- Some markets impose local testing or a local representative requirement; technical conformity alone does not secure market access.
Which decisions these results support
- Market access under radio equipment legislation
- Verification of the antenna and RF front end design
- SAR and RF exposure conformity
- Verification of module integration and the scope of reassessment
- Determining the worst case in multi-radio scenarios
Related Tests
Frequently Asked Questions About NB-IoT — RED
According to which standard is NB-IoT made?
NB-IoT is executed in scope 3GPP TS 36.521 series (NB-IoT parts), 3GPP TS 36.523, EN 301 908 serisi, GCF and PTCRB test plans, RED, ETSI and FCC. The limit values and acceptance criteria to be applied are defined in the product standard; The version valid for your product is confirmed in writing at the offer stage.
Which products does NB-IoT apply to?
Mainly applied to Water, gas and electricity meters, Indoor and basement sensors, Parking and waste management sensors and Long-lasting battery-powered monitoring devices. Whether your product is included in the scope is determined by examining its technical specifications and intended use.
Under what conditions is NB-IoT done?
The determining parameters are: bandwidth — Narrowband carrier; Defined in 3GPP, Transmitter measurements — Maximum output power, power control, spectrum emission mask, unwanted broadcasts and Receiver measurements — Reference sensitivity; at coverage expansion levels. The full terms are in the "Test Conditions" section on the page and vary depending on the product standard.
What kind of sample is needed for NB-IoT?
The device must support test SIM and test mode, Declared bands and operating modes must be documented and Coverage expansion levels must be configurable. The number of samples is determined according to the product standard and the scope to be reported.
How long does NB-IoT take?
2–5 weeks depending on the number of tapes. This duration belongs to the experiment itself; sample preparation, queuing and reporting are also evaluated. A realistic schedule for your product is given in the offer.
What is the NB-IoT result called "appropriate"?
Acceptance criteria are the limit values given in 3GPP specifications.