ICP Metal Analysis

EN ISO 11885 (water quality — determination of elements by ICP-OES)EN ISO 17294-2 (water quality — determination of elements by ICP-MS)ASTM E1479 (use of ICP atomic emission spectrometers)IEC 62321-5 (determination of Cd, Pb, Cr in restricted substances)
Metal and Metallurgy Testing laboratory work

What Is ICP Metal Analysis?

In the ICP method, the sample is put into solution and nebulised into a very high-temperature argon plasma. The plasma excites or ionises atoms; ICP-OES measures the emitted light, while ICP-MS measures the resulting ions by mass/charge ratio. ICP-MS reaches much lower concentrations.

Purpose of ICP Metal Analysis

The purpose is to measure many elements from the same solution with low uncertainty. Alloy composition verification, trace element and impurity analysis, and contaminant determination are done with this method.

Which Products Is ICP Metal Analysis Applied To?

  • Metal and alloy samples
  • Plating baths and process solutions
  • Raw material and impurity analyses
  • Water and wastewater samples
  • Recycled materials

In Which Sectors Is ICP Metal Analysis Used?

MetalAutomotiveAerospaceEnergyMachinery Manufacturing

Standards Related to ICP Metal Analysis

  • EN ISO 11885 (water quality — determination of elements by ICP-OES)
  • EN ISO 17294-2 (water quality — determination of elements by ICP-MS)
  • ASTM E1479 (use of ICP atomic emission spectrometers)
  • IEC 62321-5 (determination of Cd, Pb, Cr in restricted substances)

ICP Metal Analysis Conditions

Sample preparation
Microwave wet digestion or acid dissolution
Measurement
ICP-OES (high concentration) or ICP-MS (trace level)
internal standard
Internal standard is added to correct matrix effect
accuracy check
Certified reference material and recovery control

Equipment for ICP Metal Analysis

  • ICP-OES and/or ICP-MS system
  • Microwave digestion system
  • Ultrapure water and acid preparation setup
  • Analytical balance and volumetric measurement equipment
  • Certified reference materials

Sample Requirements for ICP Metal Analysis

  • The sample must be taken so as to represent the batch or production run.
  • Sample description, material type, and production direction if any, must be stated.
  • The standard to be applied and any customer specification must be provided together with the sample.
  • The test may be destructive; the required number of samples must be confirmed in advance.
  • Surfaces that will be tested must be protected during transport.

Duration of ICP Metal Analysis

Analysis with digestion and measurement generally takes a few working days. Since many elements can be read from the same solution, a panel request does not greatly increase duration.

ICP Metal Analysis Procedure

  1. 1The sample is weighed while protected against contamination.
  2. 2It is digested or dissolved with acid in the microwave system.
  3. 3The solution is made up to volume and diluted if required.
  4. 4An internal standard is added.
  5. 5It is fed to the ICP system and elements are measured.
  6. 6Accuracy is checked with a certified reference material.
  7. 7Results are calculated relative to sample mass.

ICP Metal Analysis Acceptance Criteria

The method standard defines how the test is performed, not what the result must be. The acceptance limit comes from the material or product standard, the customer specification, or the relevant regulation; this page therefore does not give a numerical limit.

Evaluation of Results

The result is compared against the range in the material standard or the contaminant limit in the regulation. The limit of quantification depends on the matrix and sample preparation; the reporting limit in the report is valid for these conditions.

ICP Metal Analysis Report

  • Sample description, material/product information, and batch number if any
  • Sample preparation method and conditioning conditions
  • Standard and test conditions applied
  • Instrument used and calibration status
  • Measurement results and units
  • Measurement uncertainty (if requested)
  • A statement that the result applies only to the specimen submitted for testing

Accreditation

EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.

Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.

Scope and authorisations

Related Regulations

  • Harmonised standards applied according to the product family
  • EU 765/2008 (market surveillance and accreditation framework)
  • Relevant product regulations and customer specifications

Metal and Metallurgy Testing — What Does This Testing Field Cover?

The section below describes the field that the ICP Metal Analysis test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.

Metal and metallurgical testing determines the load a metal or a welded joint can carry, how it fails and what its internal structure looks like. The output of this family is often not about the product itself but about the identity of the MATERIAL: is the steel really of the declared grade, does the weld seam deliver the strength the design assumes, does the casting contain an unacceptable internal defect?

The practical importance of the field comes from the fact that a metal part rarely fails gradually. A plastic part deforms, ages, cracks and usually gives warning. A weld seam or a fastener, by contrast, often breaks without warning — especially where fatigue and brittle fracture are involved. That is why in fields such as pressure equipment, lifting gear, structural steel and pipelines, material testing is a requirement of REGULATION rather than of design.

The family brings together three groups of methods, and each answers a different question. Mechanical tests quantify how the material behaves under load. Non-destructive examination looks for defects without damaging the part. Metallography and chemical analysis explain why the material behaves the way it does — through grain structure, phase distribution, inclusion content and alloy composition.

The acceptance criterion for these tests almost never comes from the test standard, and this is the key to understanding the field. The test standard says how the measurement is to be made; the acceptable values come from the product standard, the material grade or the fabrication code. ISO 6892-1 tells you how to run a tensile test; EN 10025 tells you what yield strength that steel must deliver. When reading a report, the product standard it was assessed against is essential.

Sampling is an inseparable part of the result in this field. Two specimens taken from the same heat may give different values depending on the direction and location they were taken from; in rolled products, specimens parallel and perpendicular to the rolling direction produce different results. Product standards therefore also govern sampling location and orientation, and the report must document this.

Method groups in this field

  • Mechanical tests

    Tensile, compression, bending, notch impact (Charpy), hardness (Brinell, Vickers, Rockwell), fatigue, creep and fracture toughness. These give the behaviour of the material under load in numerical form.

  • Non-destructive examination

    Radiography, ultrasonic examination, penetrant, magnetic particle and visual examination. It looks for surface and internal defects without damaging the part and is an indispensable step in welded fabrication.

  • Metallography

    Specimen preparation, etching and microscopic examination. Grain size, phase distribution, inclusion content, case depth and the weld heat-affected zone are assessed.

  • Chemical analysis

    Alloy composition is verified by optical emission spectrometry and wet chemistry; confirmation of the material grade runs through this step.

  • Corrosion behaviour

    Salt spray, pitting and crevice corrosion and intergranular corrosion tests. In stainless steels these can indicate the quality of the heat treatment.

Commonly confused in this field

  • A material certificate (such as EN 10204 3.1) is not a test report; it is the manufacturer's declaration. In critical applications independent verification is carried out, and the two must not be confused.
  • ASTM and ISO tensile tests measure the same quantities but use different specimen geometries; the results are not treated as directly equivalent, and whichever the specification calls for is the one applied.
  • Conversion tables between hardness and strength are APPROXIMATE. Calculating yield strength from hardness is not sufficient evidence for material acceptance.
  • In non-destructive examination, "no defect found" does not mean there is no defect; defects below the detection limit of the method may be present. The report must state the method applied and the sensitivity level.
  • A weld seam passing does not show that the welder or the procedure is qualified; these are separate processes.

Which decisions these results support

  • Verifying the material certificate and accepting incoming material
  • Approving welded fabrication; welder and procedure qualification
  • Manufacturing control of pressure equipment and structural components
  • Failure analysis and determining the root cause of field damage
  • Verifying heat treatment and surface treatment processes

Related Tests

Frequently Asked Questions About ICP Metal Analysis

ICP-OES or ICP-MS?

The expected concentration determines this. OES is sufficient for major alloying elements; MS is needed for trace-level impurities and contaminants.

Why is the sample put into solution?

Liquid is nebulised into the plasma. Complete, loss-free dissolution of the solid sample is the most critical step of the analysis; incomplete dissolution directly lowers the result.