What Is External Short Circuit — IEC 62619?
The external short circuit test is an abuse test in which a very-low-resistance connection is made between the battery terminals, and the resulting high current is evaluated for heating, gas release and fire.
Purpose of External Short Circuit — IEC 62619
The purpose is to verify that the battery remains safe in fault scenarios such as cable damage or a conductive object bridging the terminals.
Which Products Is External Short Circuit — IEC 62619 Applied To?
- Lithium-ion cell, module and pack
- Portable device batteries
- Energy storage systems
- Electric vehicle batteries
In Which Sectors Is External Short Circuit — IEC 62619 Used?
Standards Related to External Short Circuit — IEC 62619
- IEC 62619lithium battery safety in industrial applications test
External Short Circuit — IEC 62619 Conditions
- External resistance
- In UN 38.3 T.5, total external resistance less than 0.1 Ω
- Temperature
- In UN 38.3 T.5, the specimen is conditioned to approximately 57 °C
- Time
- Until the specimen temperature returns to ambient, or the duration defined in the standard
- Safety
- Explosion-protected chamber, gas venting and remote monitoring
Equipment for External Short Circuit — IEC 62619
- Low-resistance short-circuit switching rig
- High-current measurement system (shunt or current probe)
- Explosion-protected test cell and temperature chamber
- Multi-channel temperature recording
Sample Requirements for External Short Circuit — IEC 62619
- The specimen is taken into the test fully charged
- Terminal connection resistance must be measured and recorded
- The number of specimens is defined in the standard
- The test is single-use
Duration of External Short Circuit — IEC 62619
The short-circuit event itself lasts on the order of seconds; together with conditioning and observation, it takes one working day.
External Short Circuit — IEC 62619 Procedure
- 1The specimen is fully charged and conditioned to the defined temperature.
- 2Thermocouples are attached and the specimen is placed in the chamber.
- 3The terminals are bridged with a connection smaller than the defined resistance.
- 4Current and temperature are recorded continuously.
- 5Monitoring continues until the specimen temperature returns to ambient.
- 6Physical condition is assessed at the end of the observation period.
External Short Circuit — IEC 62619 Acceptance Criteria
The acceptance criterion is defined in the applied standard. In UN 38.3, the typical criteria are that the specimen's outer surface temperature does not exceed the specified limit and that no fire or explosion occurs.
Evaluation of Results
The peak current, maximum surface temperature and whether a protective element (PTC, fuse, CID) has activated are evaluated together.
External Short Circuit — IEC 62619 Report
- Applied standard and test number
- External circuit resistance and conditioning temperature
- Peak current and maximum surface temperature
- Protective element behaviour
- Observations and photographs
Accreditation
EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.
Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.
Scope and authorisationsRelated Regulations
- UN 38.3 (transport)
- UNECE R100
- EU Battery Regulation
Batarya Testleri — What Does This Testing Field Cover?
The section below describes the field that the External Short Circuit test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.
Battery testing answers three separate questions, each with its own body of standards: can the battery be transported, is it safe in use, does it deliver the declared performance? These three questions are often confused with one another, and the confusion has commercial consequences — a market cannot be entered with a transport report, and a shipment cannot be made with a product safety report.
On the transport side, UN 38.3 is a mandatory gate; a battery without that evidence cannot be shipped. On the safety side the application determines what applies: IEC 62133-2 for portable products, IEC 62619 and IEC 63056 for industrial and energy storage applications, UNECE R100, UL 2580 and ISO 6469 for electric vehicles. On the performance side, capacity, internal resistance, cycle life, self-discharge, charge acceptance and temperature-dependent behaviour are measured.
The distinction of LEVEL is essential in this family and is the subject that causes the most argument in the supply chain. Cell, module and pack are assessed separately; a certificate obtained for a cell does not demonstrate the conformity of the pack. Alongside the cells, the behaviour of the pack is determined by the battery management system, the cooling design, the mechanical structure, the interconnection arrangement and insulation coordination. Putting the cell supplier's report into the pack file is a common but inadequate approach.
Thermal runaway and its propagation are the most critical subject in the field. A lithium cell may enter a self-sustaining chemical reaction when damaged or overheated; at that point removing the heat from outside is usually not possible. Modern standards therefore treat thermal runaway of a single cell as an UNAVOIDABLE fault scenario and change the question: does the event propagate to neighbouring cells, what does it release outside the pack, and how much time is left for the user to escape?
In this field the battery management system is assessed not as an electronic board but as a SAFETY FUNCTION. It is shown that overcharge, overdischarge, overcurrent and overtemperature protections actually operate, that the system falls to the safe side in a fault, and that its software has been verified. In industrial and vehicle applications this assessment is tied to functional safety frameworks.
The regulatory side is becoming rapidly more demanding. Battery Regulation (EU) 2023/1542 goes beyond safety and introduces obligations for carbon footprint declaration, recovered content ratio, durability and capacity declaration, the battery passport, and removability for portable batteries. This takes the scope of testing beyond classical safety tests.
Method groups in this field
Electrical abuse
Overcharge, overdischarge, external short circuit, forced discharge and unbalanced charging. This is where it is seen whether the protection circuits actually work.
Mechanical abuse
Vibration, shock, crush, penetration, free fall and tipping. It is monitored whether internal short circuit conditions arise.
Thermal tests
Temperature cycling, thermal shock, high temperature storage, fire exposure and thermal runaway propagation.
Environmental tests
Humidity, low pressure, salt spray and, where required, immersion; these come to the fore in vehicle and outdoor applications.
Performance measurements
Capacity, energy and power, internal resistance, efficiency, cycle life, calendar life and temperature-dependent behaviour.
BMS verification
Verification of protection thresholds, the cell balancing function, communications and fault response.
Commonly confused in this field
- UN 38.3 is not a product safety certificate; it only demonstrates transport conformity.
- A cell certificate does not demonstrate pack conformity. The pack is assessed separately with its own architecture.
- Two packs built from the same cell give different results; cooling, interconnection and mechanical structure are decisive.
- A performance test is not a safety test. A cycle life report does not satisfy safety requirements.
- For an electric vehicle battery, a UL 2580 report and UNECE R100 approval are not the same thing; one is a standards assessment, the other a type approval regime.
- A vehicle battery moved into a second-life application enters a new usage profile; the earlier assessment does not carry over directly.
Which decisions these results support
- Transport conformity and the test summary for shipment
- Product safety declaration and market access
- Performance, durability and carbon footprint declarations under the Battery Regulation
- Assessing the impact of a cell supplier or BMS change
- Site acceptance processes for an energy storage system
Related Tests
Frequently Asked Questions About External Short Circuit — IEC 62619
Is the test still valid if a protective element activates?
Yes. Activation of elements such as a fuse, PTC or CID is expected design behaviour and is noted separately in the report. The criterion is the absence of fire and explosion.