Battery Testing · Abuse

Overdischarge — IEC 62619

IEC 62619
Batarya Testleri laboratory work

What Is Overdischarge — IEC 62619?

The overdischarge test is an abuse test in which the cell or battery is discharged below its declared lower cut-off voltage, if necessary to voltage reversal, to evaluate its safety behaviour. It is referred to as forced discharge in UN 38.3.

Purpose of Overdischarge — IEC 62619

The purpose is to verify that the battery does not lead to fire or explosion in fault scenarios such as one of the series-connected cells being driven into reversal.

Which Products Is Overdischarge — IEC 62619 Applied To?

  • Lithium-ion cells
  • Series-connected battery modules
  • Portable device batteries

In Which Sectors Is Overdischarge — IEC 62619 Used?

BatteryElectric VehicleAutomotiveEnergyElectronics

Standards Related to Overdischarge — IEC 62619

  • IEC 62619lithium battery safety in industrial applications test

Overdischarge — IEC 62619 Conditions

Discharge current
Current defined in the standard; the maximum declared discharge current in UN 38.3
Termination
Duration defined in the standard, or a reverse-voltage level
Environment
Ambient temperature defined in the standard
Safety
Explosion-protected chamber and remote monitoring

Equipment for Overdischarge — IEC 62619

  • Programmable electronic load / power supply
  • Explosion-protected test cell
  • Temperature and voltage recording system
  • Gas venting and extinguishing system

Sample Requirements for Overdischarge — IEC 62619

  • The number of specimens is defined in the standard
  • The specimen is taken into the test at the defined state of charge
  • The test is single-use
  • Declared discharge limits are required

Duration of Overdischarge — IEC 62619

Together with the observation period, it is typically one working day.

Overdischarge — IEC 62619 Procedure

  1. 1The specimen is identified and its initial values are recorded.
  2. 2The specimen is placed in the explosion-protected chamber and thermocouples are attached.
  3. 3Forced discharge at the current defined in the standard is applied.
  4. 4Monitoring continues even if the voltage passes into reversal.
  5. 5The test is stopped at the end of the defined period and the observation period begins.
  6. 6Physical condition and mass loss are assessed.

Overdischarge — IEC 62619 Acceptance Criteria

The acceptance criterion is defined in the applied standard; typically, the absence of fire and explosion during the test and observation period.

Evaluation of Results

Temperature rise, gas release and deformation are assessed. Capacity loss is not a criterion in this test; the specimen becomes unusable.

Overdischarge — IEC 62619 Report

  • Applied standard and test number
  • Discharge current and duration
  • Temperature and voltage curves
  • Observations and photographs

Accreditation

EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.

Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.

Scope and authorisations

Related Regulations

  • UN 38.3 (transport)
  • EU Battery Regulation

Batarya Testleri — What Does This Testing Field Cover?

The section below describes the field that the Overdischarge test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.

Battery testing answers three separate questions, each with its own body of standards: can the battery be transported, is it safe in use, does it deliver the declared performance? These three questions are often confused with one another, and the confusion has commercial consequences — a market cannot be entered with a transport report, and a shipment cannot be made with a product safety report.

On the transport side, UN 38.3 is a mandatory gate; a battery without that evidence cannot be shipped. On the safety side the application determines what applies: IEC 62133-2 for portable products, IEC 62619 and IEC 63056 for industrial and energy storage applications, UNECE R100, UL 2580 and ISO 6469 for electric vehicles. On the performance side, capacity, internal resistance, cycle life, self-discharge, charge acceptance and temperature-dependent behaviour are measured.

The distinction of LEVEL is essential in this family and is the subject that causes the most argument in the supply chain. Cell, module and pack are assessed separately; a certificate obtained for a cell does not demonstrate the conformity of the pack. Alongside the cells, the behaviour of the pack is determined by the battery management system, the cooling design, the mechanical structure, the interconnection arrangement and insulation coordination. Putting the cell supplier's report into the pack file is a common but inadequate approach.

Thermal runaway and its propagation are the most critical subject in the field. A lithium cell may enter a self-sustaining chemical reaction when damaged or overheated; at that point removing the heat from outside is usually not possible. Modern standards therefore treat thermal runaway of a single cell as an UNAVOIDABLE fault scenario and change the question: does the event propagate to neighbouring cells, what does it release outside the pack, and how much time is left for the user to escape?

In this field the battery management system is assessed not as an electronic board but as a SAFETY FUNCTION. It is shown that overcharge, overdischarge, overcurrent and overtemperature protections actually operate, that the system falls to the safe side in a fault, and that its software has been verified. In industrial and vehicle applications this assessment is tied to functional safety frameworks.

The regulatory side is becoming rapidly more demanding. Battery Regulation (EU) 2023/1542 goes beyond safety and introduces obligations for carbon footprint declaration, recovered content ratio, durability and capacity declaration, the battery passport, and removability for portable batteries. This takes the scope of testing beyond classical safety tests.

Method groups in this field

  • Electrical abuse

    Overcharge, overdischarge, external short circuit, forced discharge and unbalanced charging. This is where it is seen whether the protection circuits actually work.

  • Mechanical abuse

    Vibration, shock, crush, penetration, free fall and tipping. It is monitored whether internal short circuit conditions arise.

  • Thermal tests

    Temperature cycling, thermal shock, high temperature storage, fire exposure and thermal runaway propagation.

  • Environmental tests

    Humidity, low pressure, salt spray and, where required, immersion; these come to the fore in vehicle and outdoor applications.

  • Performance measurements

    Capacity, energy and power, internal resistance, efficiency, cycle life, calendar life and temperature-dependent behaviour.

  • BMS verification

    Verification of protection thresholds, the cell balancing function, communications and fault response.

Commonly confused in this field

  • UN 38.3 is not a product safety certificate; it only demonstrates transport conformity.
  • A cell certificate does not demonstrate pack conformity. The pack is assessed separately with its own architecture.
  • Two packs built from the same cell give different results; cooling, interconnection and mechanical structure are decisive.
  • A performance test is not a safety test. A cycle life report does not satisfy safety requirements.
  • For an electric vehicle battery, a UL 2580 report and UNECE R100 approval are not the same thing; one is a standards assessment, the other a type approval regime.
  • A vehicle battery moved into a second-life application enters a new usage profile; the earlier assessment does not carry over directly.

Which decisions these results support

  • Transport conformity and the test summary for shipment
  • Product safety declaration and market access
  • Performance, durability and carbon footprint declarations under the Battery Regulation
  • Assessing the impact of a cell supplier or BMS change
  • Site acceptance processes for an energy storage system

Related Tests

Frequently Asked Questions About Overdischarge — IEC 62619

According to which standard is Overdischarge made?

Overdischarge is executed in scope UN 38.3 T.8, IEC 62133-2, IEC 62619 and UL 1642. The limit values ​​and acceptance criteria to be applied are defined in the product standard; The version valid for your product is confirmed in writing at the offer stage.

Which products does Overdischarge apply to?

Mainly applied to Lithium-ion cells, Series-connected battery modules and Portable device batteries. Whether your product is included in the scope is determined by examining its technical specifications and intended use.

Under what conditions is Overdischarge done?

The determining parameters are: Discharge current — Current defined in the standard; the maximum declared discharge current in UN 38.3, Termination — Duration defined in the standard, or a reverse-voltage level and Environment — Ambient temperature defined in the standard. The full terms are in the "Test Conditions" section on the page and vary depending on the product standard.

What kind of sample is needed for Overdischarge?

The number of specimens is defined in the standard, The specimen is taken into the test at the defined state of charge and The test is single-use. The number of samples is determined according to the product standard and the scope to be reported.

How long does Overdischarge take?

Together with the observation period, it is typically one working day. This duration belongs to the experiment itself; sample preparation, queuing and reporting are also evaluated. A realistic schedule for your product is given in the offer.

What is the Overdischarge result called "appropriate"?

The acceptance criterion is defined in the applied standard; typically, the absence of fire and explosion during the test and observation period.