Vibration and Shock · Vibration and shock testing

Classical Shock

IEC 60068-2-27MIL-STD-810 Method 516RTCA DO-160 Section 7IEC 61373IEC 60068MIL-STD-810RTCA DO-160SAEISO 16750UN 38.3
Vibration and Shock laboratory work

What Is Classical Shock?

The classical shock test is a shock test in which mathematically defined pulse shapes (half-sine, terminal peak sawtooth, trapezoidal) specified in standards are applied to the sample.

Purpose of Classical Shock

The purpose is to verify, using defined and repeatable pulse shapes, that sudden impacts during transport and service do not damage the product.

Which Products Is Classical Shock Applied To?

  • Electronic units
  • Automotive and rail equipment
  • Aerospace avionics
  • Battery modules

In Which Sectors Is Classical Shock Used?

AutomotiveAerospaceDefenceDemiryoluLogistics

Standards Related to Classical Shock

  • IEC 60068-2-27mechanical shock test test
  • MIL-STD-810 Method 516
  • RTCA DO-160 Section 7
  • IEC 61373vibration and shock in railway vehicle equipment test
  • IEC 60068series of environmental testing methods test
  • MIL-STD-810environmental engineering assessments and laboratory tests test
  • RTCA DO-160Environmental conditions and test methods in aviation equipment test
  • SAEautomotive and aerospace engineering standards test
  • ISO 16750Environmental conditions in vehicle electrical/electronic equipment test
  • UN 38.3Transport safety tests on lithium batteries test

Classical Shock Conditions

Impact shape
Half-sine, terminal peak sawtooth veya trapezoidal
Peak acceleration and duration
Defined in the specification (g and ms)
Number of shocks
Defined number of points in each axis and direction
Tolerans
The impact shape must remain within the tolerance band given in the standard.

Equipment for Classical Shock

  • Shock test machine
  • Accelerometer and shock analysis system
  • Programmer pads
  • Mounting fixture

Sample Requirements for Classical Shock

  • The fixture must be rigid enough not to distort the shock
  • Function must be checked before the test
  • Pulse directions must be defined

Duration of Classical Shock

Depends on the number of pulses; typically half to one working day.

Classical Shock Procedure

  1. 1Pulse shape, amplitude and duration are set.
  2. 2The profile is verified with an empty fixture.
  3. 3Pulses are applied in each axis and direction.
  4. 4Pulse curves are recorded.
  5. 5Function and visual inspection are carried out.

Classical Shock Acceptance Criteria

The acceptance criterion is defined in the specification: no structural damage and continuity of function.

Evaluation of Results

The measured pulse curve remaining within the tolerance band is required for the test's validity.

Classical Shock Report

  • Applied standard and pulse shape
  • Peak acceleration, duration and number of pulses
  • Axes and directions
  • Pulse curves
  • Functional status

Accreditation

EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.

Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.

Scope and authorisations

Related Regulations

  • Automotive, railway and aviation specifications

Vibration and Shock — What Does This Testing Field Cover?

The section below describes the field that the Classical Shock test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.

Vibration and shock testing shows whether a product withstands mechanical dynamic loads. The two phenomena are distinct: vibration is a continuous and repeated loading, while shock is a single instantaneous impact at high acceleration. They produce different failure modes and are required separately.

The failure produced by vibration is FATIGUE: a solder joint cracks, a cable sheath abrades, a screw loosens, a connector loses contact. The failure produced by shock is FRACTURE: a brittle component shatters, a bracket breaks, a board comes out of its holder. Testing a product under vibration therefore does not show that it also withstands shock.

Vibration is applied in three forms, each giving different information. Sine vibration sweeps at a single frequency; it is used to find the resonant frequencies of the product and is very valuable at the design stage. Random vibration represents the broadband nature of the real environment and is preferred as evidence of durability. Sine-on-random and random-on-random profiles simulate together the broadband noise superimposed on dominant frequencies from engines and rotors — this is necessary in helicopter and turboprop applications.

RESONANCE is the concept at the centre of the field. Every structure has its own natural frequencies; as the excitation frequency approaches one of them the amplitude grows and the product is exposed to an acceleration many times the input level. A resonance search is therefore carried out before the test, and a design change often takes the form of shifting the resonance rather than lowering the level.

In this family the FIXTURE is part of the result, and this is the most frequently overlooked point. How the specimen is attached to the shaker directly changes the energy transmitted and the resonance behaviour. A poorly designed fixture brings its own resonances into play and imposes a load the product would not otherwise see, or conversely damps the real load and protects the product. Results obtained with different fixtures cannot be compared.

The choice of measurement point also determines the result. The control accelerometer is placed on the fixture and monitoring accelerometers at critical points of the product; the report must document these positions. Accelerations measured at different points in the same test can differ markedly.

Profiles are divided by application area: transport vibration (packaging and shipping), vehicle vibration (by mounting location), rail (EN 61373 categories), aviation (DO-160 sections), military (MIL-STD-810 methods) and battery transport (UN 38.3 T3). The same product passes through different profiles under different programmes.

Method groups in this field

  • Sine vibration

    Determining resonances by frequency sweep and withstand at defined frequencies; the most informative test at the design stage.

  • Random vibration

    Durability with a broadband power spectral density profile; the approach that best represents the real environment.

  • Combined profiles

    Sine-on-random and random-on-random; for dominant frequencies arising from rotating machinery.

  • Classical shock

    Defined acceleration and duration with half-sine, sawtooth and trapezoidal pulse shapes.

  • Free fall and toppling

    Realistic drop scenarios arising from handling; decisive for portable products.

  • Resonance search and monitoring

    Detection of structural change (cracking, loosening) by sweeps before and after the test.

Commonly confused in this field

  • Shock and vibration are not the same test; one produces fracture and the other fatigue, and they are required separately.
  • A report that does not document the fixture cannot be compared; a fixture can bring its own resonance into play.
  • Levels come from the product standard or the programme specification; the standard does not define a single universal level.
  • Without a resonance sweep before and after the test, structural damage can go unnoticed; the product may appear to work while being cracked internally.
  • The position of the measurement point must be reported; accelerations measured at different points in the same test differ markedly.
  • If the product is not operated during the test, intermittent loss of contact remains invisible.

Which decisions these results support

  • Verification of transport and in-use durability
  • Transport and vehicle vibration conformity for batteries
  • Rail, aviation and defence qualification files
  • Root cause analysis of solder, connector and joint failures
  • The decision to shift a resonance through a design change

Related Tests

Frequently Asked Questions About Classical Shock

According to which standard is Classical Shock made?

Classical Shock is executed in scope IEC 60068-2-27, MIL-STD-810 Method 516, RTCA DO-160 Section 7 and IEC 61373. The limit values ​​and acceptance criteria to be applied are defined in the product standard; The version valid for your product is confirmed in writing at the offer stage.

Which products does Classical Shock apply to?

Mainly applied to Electronic units, Automotive and rail equipment, Aerospace avionics and Battery modules. Whether your product is included in the scope is determined by examining its technical specifications and intended use.

Under what conditions is Classical Shock done?

The determining parameters are: Impact shape — Half-sine, terminal peak sawtooth veya trapezoidal, Peak acceleration and duration — Defined in the specification (g and ms) and Number of shocks — Defined number of points in each axis and direction. The full terms are in the "Test Conditions" section on the page and vary depending on the product standard.

What kind of sample is needed for Classical Shock?

The fixture must be rigid enough not to distort the shock, Function must be checked before the test and Pulse directions must be defined. The number of samples is determined according to the product standard and the scope to be reported.

How long does Classical Shock take?

Depends on the number of pulses; typically half to one working day. This duration belongs to the experiment itself; sample preparation, queuing and reporting are also evaluated. A realistic schedule for your product is given in the offer.

What is the Classical Shock result called "appropriate"?

The acceptance criterion is defined in the specification: no structural damage and continuity of function.