Loading

Cosmetics Testing · Cosmetics

Viscosity

ISO 2555 (apparent viscosity by Brookfield-type rotational viscometer)ISO 3219 (polymers and resins — rotational viscometer)ASTM D2196 (rheological properties of non-Newtonian materials)Product internal specifications and stability plan
Kozmetik Testleri laboratory work

What Is Viscosity?

Viscosity is a liquid's resistance to flow. Most cosmetic products are non-Newtonian: viscosity varies with the applied shear rate. The spindle used, rotation speed, temperature and dwell time are therefore an integral part of the result and are given together in the report.

Purpose of Viscosity

The purpose is to translate the product's consistency into a number to monitor batch-to-batch consistency and catch a change in consistency early in the stability study. Consistency is one of the properties a consumer assesses first.

Which Products Is Viscosity Applied To?

  • Creams, lotions and gels
  • Shampoos and shower gels
  • Liquid soaps and cleansers
  • Foundation and liquid makeup products
  • Hair conditioners and masks

In Which Sectors Is Viscosity Used?

CosmeticsPersonal CareRetailChemistry

Standards Related to Viscosity

  • ISO 2555 (apparent viscosity by Brookfield-type rotational viscometer)
  • ISO 3219 (polymers and resins — rotational viscometer)
  • ASTM D2196 (rheological properties of non-Newtonian materials)
  • Product internal specifications and stability plan

Viscosity Conditions

Temperature
The measurement is made at constant temperature; temperature is indicated in the report
Miles and speed
It is selected based on the consistency of the product and kept the same in each measurement.
Dwell time
The reading is taken at the end of the defined rotation period
Specimen preparation
The sample is measured without stirring and without air bubbles

Equipment for Viscosity

  • Rotational (Brookfield-type) viscometer and spindle set
  • Temperature-controlled water bath
  • Helipath stand (for thick products)
  • Sample containers and thermometer

Sample Requirements for Viscosity

  • The product must be sent in its original, unopened packaging.
  • Batch number, manufacturing and expiry dates must be stated.
  • The ingredients list (INCI) and formulation information, if any, must be shared.
  • The required quantity varies by number of analyses; confirmation must be obtained before shipment.
  • Light- and temperature-sensitive products must be transported under suitable conditions.

Duration of Viscosity

The measurement itself takes minutes; the time waited for temperature equilibration is added.

Viscosity Procedure

  1. 1The sample is brought to measurement temperature and allowed to equilibrate.
  2. 2A spindle and speed suited to the product's consistency are selected.
  3. 3The spindle is immersed in the sample without creating air bubbles.
  4. 4The instrument is run and rotated for the defined duration.
  5. 5A reading is taken and viscosity calculated.
  6. 6The measurement is repeated and averaged.
  7. 7Spindle, speed and temperature are recorded together with the result.

Viscosity Acceptance Criteria

The acceptance criterion for cosmetic products does not come from a single test but from the product's safety assessment report and the regulation. EU 1223/2009 and the Cosmetics Regulation define prohibited and restricted substances, microbiological expectations, and labelling requirements; this page therefore does not give a fixed limit.

Evaluation of Results

The result is compared against the consistency range in the product's internal specification. Measurements taken with a different spindle or speed cannot be compared with one another; batch comparison is meaningful only under the same conditions.

Viscosity Report

  • Product name, batch number, and packaging information
  • Sample receipt date and storage conditions
  • Method applied and reference standard
  • Test conditions and conditioning, if any
  • Measurement results and units
  • Measurement uncertainty (if requested)
  • A statement that the result applies only to the specimen submitted for testing

Accreditation

EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.

Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.

Scope and authorisations

Related Regulations

  • EU 1223/2009 Cosmetic Products Regulation
  • Cosmetics Regulation (Türkiye)
  • Cosmetic Product Safety Report (CPSR) requirements
  • ISO 22716 (good manufacturing practice in cosmetics)

Kozmetik Testleri — What Does This Testing Field Cover?

The section below describes the field that the Viscosity test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.

Cosmetics testing shows that a product stays microbiologically safe throughout its use, delivers the performance it claims and contains no restricted substances. There is NO PRODUCT APPROVAL in this family: no authority approves a cosmetic product; responsibility rests entirely with the manufacturer and with the responsible person established in the EU.

This responsibility model shapes how the field works. Before the product is placed on the market a product information file (PIF) is prepared, a safety assessment (CPSR) is carried out and notification is completed. Inspection comes afterwards and asks for the file; if the file is incomplete the product is withdrawn from the market. Test reports form the evidence base of that file.

On the microbiological side there are two different questions and each is answered by a separate test. The CURRENT microbiological quality of the product is measured by enumeration and testing for specified microorganisms. The EFFECTIVENESS of the preservative system is examined by deliberately inoculating the product with microorganisms (challenge test): can the product resist repeated contamination throughout its use? A jar of cream is touched by a finger at every use; the preservative system must cope with that.

On the performance side, claim substantiation studies are carried out. For sunscreens, determination of SPF and UVA protection and measurement of water resistance are mandatory and are the basis of the value declared on the label. Evidence is also produced by in vivo or in vitro methods for claims such as moisturisation, appearance of wrinkles, hair care and colour retention.

On the chemical side, banned and restricted substances are screened: heavy metals, prohibited colorants, preservative concentrations, UV filter levels and contaminants such as nitrosamines. Products containing nanomaterials carry a separate notification obligation.

The BAN ON ANIMAL TESTING is the most defining constraint of the field. Animal testing cannot be carried out on finished products or ingredients, and a product tested on animals cannot be placed on the market. Alternative in vitro methods (reconstructed human skin models, cell culture based tests) are therefore at the centre of the field, and toxicological assessment rests largely on existing data, read-across approaches and in vitro results.

Stability and packaging compatibility studies determine shelf life and the period after opening (PAO). The interaction of the product with its packaging is also assessed: an active substance may migrate into the packaging, and substances that should not be present may pass from the packaging into the product.

On the process side, good manufacturing practice is demonstrated through ISO 22716; this is separate from product testing but a mandatory part of the file.

Method groups in this field

  • Microbiological quality

    Enumeration of aerobic mesophilic bacteria, yeasts and moulds; testing for Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans and E. coli.

  • Preservative efficacy

    Resistance of the preservative system to repeated contamination by challenge test (ISO 11930).

  • Sun protection

    In vivo SPF determination, in vitro UVA protection determination, water resistance and critical wavelength measurements.

  • Chemical analysis

    Heavy metals, banned and restricted substances, quantification of preservatives and UV filters, contaminant screening.

  • Safety assessment

    In vitro irritation and sensitisation methods, toxicological risk assessment, exposure calculations.

  • Stability and compatibility

    Real-time and accelerated stability, packaging compatibility, PAO determination, sensory and physicochemical monitoring.

Commonly confused in this field

  • There is NO CE marking on cosmetics; conformity is demonstrated through the PIF, the safety assessment and notification.
  • The responsible person must be established in the EU; unless the exporter arranges this, the product cannot be placed on the market.
  • Microbiological quality and preservative efficacy are different tests; a product that comes out clean may still have a weak preservative system.
  • The animal testing ban covers ingredients too; animal test data generated for another market creates a problem of use.
  • An SPF claim must be supported by measurement; a formulation change requires a new measurement.
  • A change of packaging may require the stability and compatibility studies to be repeated.

Which decisions these results support

  • The product information file and the safety assessment
  • Verification of the preservative system design
  • Substantiation of SPF and efficacy claims
  • Determining shelf life and the period after opening
  • Compliance with destination market restrictions for export

Related Tests

Frequently Asked Questions About Viscosity

Why are the spindle and speed stated in the report?

Most cosmetic products behave shear-rate-dependently. A different spindle or speed on the same product gives a different number; a viscosity value given without stating the condition cannot be interpreted.

How much does temperature affect it?

Very much; a difference of a few degrees can cause a noticeable change. The measurement is therefore made in a temperature-controlled environment and the value is stated in the report.

We use cookies required for the site to work. With your permission we also add an analytics cookie to understand how pages are used. Cookie Policy