Furniture Testing · Furniture tests

Stability

TS EN 1022 (seating — determination of stability)TS EN 1730 (tables — stability tests)TS EN 16121 / 16122 (storage furniture — stability)ICH Q1A(R2) (stability testing of new drug substances and products)ICH Q1B (photostability)ISO 18811 (guidelines on stability testing of cosmetic products)
Mobilya Testleri laboratory work

What Is Stability?

Stability carries two distinct meanings depending on the product group. In FURNITURE, stability means resistance to tipping over: loads defined in the standard are applied to the product at defined points, and whether it tips is observed. In COSMETIC AND PHARMACEUTICAL PRODUCTS, stability is monitoring under controlled temperature and humidity conditions whether the product retains its physical, chemical and microbiological properties over its shelf life.

Purpose of Stability

In furniture, the purpose is to verify the product does not tip over under foreseeable use, particularly children climbing on it — tipped-over cabinets and TV units are a serious source of injury. In cosmetics and pharmaceuticals, the purpose is to support the declared shelf life and storage condition with data.

Which Products Is Stability Applied To?

  • Cabinets, bookcases, chests of drawers and TV stands
  • Tables and chairs
  • Cosmetic products (cream, lotion, shampoo)
  • Pharmaceutical formulations and packaged products
  • Food supplements

In Which Sectors Is Stability Used?

FurnitureRetailConsumer ProductsCosmeticsPharmaceuticalsBiotechnology

Standards Related to Stability

  • TS EN 1022 (seating — determination of stability)
  • TS EN 1730 (tables — stability tests)
  • TS EN 16121 / 16122 (storage furniture — stability)
  • ICH Q1A(R2) (stability testing of new drug substances and products)
  • ICH Q1B (photostability)
  • ISO 18811 (guidelines on stability testing of cosmetic products)

Stability Conditions

Furniture
Vertical and horizontal loads defined in the standard, applied at defined points
Pharmaceutical — long term
Long-term storage condition defined in ICH Q1A, chosen according to climatic zone
Pharmaceutical — accelerated
Accelerated condition defined in ICH Q1A; typically monitored for six months
Cosmetics
Monitoring under room, high-temperature, low-temperature and cyclic conditions

Equipment for Stability

  • Stability (tip-over) test platform and loading rigs
  • Climate chambers (temperature and humidity controlled)
  • Photostability chamber
  • HPLC and analytical measurement systems
  • pH meter, viscometer and microbiological facilities

Sample Requirements for Stability

  • A fully assembled product for furniture; the declared use class must be provided
  • Specimen with its market packaging for cosmetics and pharmaceuticals
  • A separate specimen is required for each time point to be pulled
  • Formulation, packaging material and batch information must be provided

Duration of Stability

The furniture stability test is short. Cosmetic and pharmaceutical stability studies are inherently long: the accelerated condition typically runs six months, and the long-term study runs for the declared shelf life, with specimens pulled at defined time points.

Stability Procedure

  1. 1For furniture, the product is placed on the defined floor and conditioned.
  2. 2Vertical and horizontal loads are applied at the points defined in the standard; tipping is observed.
  3. 3For cosmetics and pharmaceuticals, specimens are placed in chambers at the defined conditions.
  4. 4Specimens are pulled at the defined time points.
  5. 5Appearance, pH, viscosity, active substance content, degradation products and microbiological properties are measured.
  6. 6Results are assessed as a trend over time.

Stability Acceptance Criteria

In furniture, the acceptance criterion is that the product does not tip over under the defined loads. In cosmetics and pharmaceuticals, it is that specification limits are maintained over the shelf life; the limits are defined in the product's own specification, and come from the pharmacopoeia monograph where one exists.

Evaluation of Results

In furniture, each loading point is assessed separately; passing at one point does not cover another. In pharmaceuticals and cosmetics, accelerated results alone do not determine shelf life — they support the long-term data; if a significant change is seen, an intermediate condition study is required.

Stability Report

  • Product identification and test scope
  • Loads applied, points and tip-over observation for furniture
  • Storage conditions and time points for cosmetics and pharmaceuticals
  • Measurement results for each time point
  • Trend assessment and conclusion

Accreditation

EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.

Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.

Scope and authorisations

Related Regulations

  • (EU) 2023/988 General Product Safety Regulation
  • (EC) 1223/2009 Cosmetic Products Regulation
  • 2001/83/EC Directive on Medicinal Products for Human Use

Mobilya Testleri — What Does This Testing Field Cover?

The section below describes the field that the Stability test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.

Furniture testing shows that a product stays safe and functional throughout its expected service life. Tests are run with loading cycles representing real use: sitting, leaning back, opening and closing drawers, loading doors, loading shelves and tipping.

The logic of the field rests on the NUMBER OF CYCLES. Sitting on a chair once shows nothing; repeating it tens of thousands of times reveals structural weaknesses. Furniture tests therefore combine static loading with fatigue cycles and define different levels according to intensity of use: domestic use, commercial use and heavy commercial use mean different cycle counts for the same product.

TIP-OVER SAFETY carries particular weight in this family. Because storage furniture tipping onto a child has caused serious injuries and deaths, product standards define separate tests for it: loading with drawers open, hanging from a door and climbing scenarios are simulated. In the United States this subject has become a legislative heading of its own and has produced a mandatory specification.

The second axis is chemical and concerns indoor air quality. Formaldehyde release from wood-based panels and volatile organic compound emissions from coatings and textile components are measured. For formaldehyde, a restriction regulation applies on the EU side and CARB Phase 2 and TSCA Title VI limits in North America; these limits differ and export requires assessment against the destination market.

The third axis is flammability. In upholstered furniture the filling material and the upholstery fabric are assessed together; real ignition sources such as a cigarette and a match flame are simulated. The United Kingdom has historically applied the strictest national regime on this subject.

Surface durability is the fourth axis: abrasion, scratching, stain resistance, heat and moisture resistance, light fastness. These tests show how well the product will keep its appearance and shape commercial expectations particularly for kitchen and office furniture.

There is NO sector-specific CE regime for consumer furniture; safety is demonstrated under the general product safety framework using EN durability standards. For furniture permanently fixed into a structure, construction products legislation may come into play. This distinction matters in project work: a kitchen cabinet and a built-in system fabricated in place can fall under different regimes.

Method groups in this field

  • Seating

    Seat and back loading cycles, arm strength, drop test, tipping resistance, leg and joint strength.

  • Tables and work surfaces

    Static and cyclic loading, horizontal strength, tipping, surface durability.

  • Storage furniture

    Shelf and door loading, drawer cycles, tip-over safety and climbing scenarios.

  • Beds and mattresses

    Durability cycles, edge strength, loss of thickness after loading.

  • Emissions

    Formaldehyde release (chamber, perforator and gas analysis methods), VOC emission test chamber measurements.

  • Surface and flammability

    Abrasion, scratching, staining, heat and moisture resistance; ignitability in upholstered furniture.

Commonly confused in this field

  • A result obtained for domestic use does not support a claim of commercial use; the cycle counts and levels are different.
  • Tip-over safety is a separate test; passing the durability cycles does not demonstrate tip-over safety.
  • Formaldehyde limits differ by market; EU compliance does not mean CARB/TSCA compliance.
  • Flammability in upholstered furniture is valid for the COMBINATION of fabric and filling; a change of fabric requires reassessment.
  • A result obtained on one model does not cover the whole range; differences in size, material and joints may require separate assessment.

Which decisions these results support

  • Determining the durability class for commercial and domestic use
  • Tip-over safety and child safety conformity
  • Compliance with formaldehyde and VOC emission limits
  • Meeting tender and project specification requirements
  • Determining destination market requirements for export

Related Tests

Frequently Asked Questions About Stability

We anchor the cabinet to the wall — is a stability test still needed?

Yes. Product standards address both anchored and unanchored conditions, since the user may not fit the anchor. Supplying the anchoring hardware with the product and clear instructions is a separate compliance matter.

Does accelerated stability determine shelf life?

Not on its own. Accelerated data gives an early prediction and can support a provisional shelf-life claim, but the final shelf life is supported by long-term study data.

Are stability and challenge testing the same thing in cosmetics?

No. Stability studies track the product's change over time; challenge testing (preservative efficacy) deliberately inoculates the product with micro-organisms to show the preservative system works. Both are required together in the Product Information File.