Short Circuit — IEC 60335

IEC 60335IEC 62368IEC 61010
Electrical Safety laboratory work

What Is Short Circuit — IEC 60335?

The short-circuit test is a test in which the device or assembly is exposed to the expected short-circuit current, evaluating whether the protective elements safely interrupt the current and the structure retains its integrity.

Purpose of Short Circuit — IEC 60335

The purpose is to verify that personnel and facility safety are preserved under short circuit, and that arc and fire risk are contained.

Which Products Is Short Circuit — IEC 60335 Applied To?

  • Electrical panels and distribution systems
  • Circuit breakers and fuses
  • Motor control centres
  • Battery systems
  • Power supplies

In Which Sectors Is Short Circuit — IEC 60335 Used?

ElectricalElectronicsMachineryMedical Device

Standards Related to Short Circuit — IEC 60335

  • IEC 60335Safety in home and similar electrical devices test
  • IEC 62368Security in audio, video and information technology devices test
  • IEC 61010Safety in measuring, control and laboratory devices test

Short Circuit — IEC 60335 Conditions

Prospective short-circuit current
Defined in the installation or specification (in kA)
Power factor
Defined in standard
Time
The protective element's breaking time
Test sequence
Operation sequences such as O-CO-CO defined in the standard

Equipment for Short Circuit — IEC 60335

  • High-power short-circuit test laboratory
  • Short-circuit generator or transformer bank
  • Oscilloscope and current measurement system
  • Arc-protection rig

Sample Requirements for Short Circuit — IEC 60335

  • The specimen must be in its real installation configuration
  • The protective element's type and rating must be documented
  • The prospective short-circuit current must be defined
  • The test may be single-use

Duration of Short Circuit — IEC 60335

The test duration is milliseconds; together with preparation and evaluation, several days.

Short Circuit — IEC 60335 Procedure

  1. 1The prospective short-circuit current and test sequence are determined.
  2. 2The specimen is set up in the test rig.
  3. 3The short circuit is applied and current/voltage are recorded at high speed.
  4. 4The protective element's breaking behaviour is examined.
  5. 5Structural damage and arc traces are assessed.

Short Circuit — IEC 60335 Acceptance Criteria

The acceptance criterion is defined in the relevant standard: the protective element interrupting the current, preservation of enclosure integrity, and containment of arc emission.

Evaluation of Results

Breaking time, peak current and I²t values are evaluated. Enclosure deformation and arc traces are recorded.

Short Circuit — IEC 60335 Report

  • Applied standard and test sequence
  • Prospective short-circuit current and power factor
  • Measured current and voltage curves
  • Protective behaviour and breaking time
  • Structural assessment

Accreditation

EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.

Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.

Scope and authorisations

Related Regulations

  • LVD 2014/35/EU
  • Machinery Directive

Electrical Safety — What Does This Testing Field Cover?

The section below describes the field that the Short Circuit test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.

Electrical safety testing shows that a device poses no risk of electric shock, fire or injury to the user in normal use and under foreseeable fault conditions. This family is the test group most often requested when a product enters the market; almost every electrically operated product passes through this gate.

The logic of the field rests on a single assumption: FAULTS WILL HAPPEN. Insulation will age, a component will short, a cable will break, the user will misuse the device. Standards therefore test not only normal operation but also single fault conditions. The sentence "the device works correctly" is not evidence in this field; the evidence is that the device stays safe when it fails.

Assessment addresses three layers together. In the constructional layer, insulation distances (creepage and clearance), protective barriers, earthing continuity, enclosure strength and component selection are examined — this layer is largely a matter of inspection and measurement rather than testing. In the electrical layer, dielectric strength, leakage current, insulation resistance and behaviour under fault conditions are measured. In the thermal layer, temperature rise in normal and abnormal operation is monitored; an overheating component is both a fire risk and a risk of insulation breakdown.

Which standard applies is determined by WHAT THE PRODUCT IS, and that decision affects the entire outcome. Household appliances fall under the IEC 60335 series, information technology and audio/video products under IEC 62368-1, measurement and laboratory equipment under IEC 61010-1, and medical devices under IEC 60601-1. A report obtained under the wrong standard is not accepted in the file even if the measurements it contains are correct.

Component conformity is often overlooked in this field. The safety of the device rests on the conformity of the transformer, optocoupler, fuse, switch and power supply it uses. The list of critical components and the certification status of each is part of the technical file; a change of component reopens the safety assessment.

Method groups in this field

  • Constructional examination

    Insulation distances, barriers, earthing arrangement, accessibility and selection of critical components are examined. It comes before testing and many non-conformities are caught here.

  • Dielectric strength

    It is verified that the insulation withstands the defined voltage. It must not be confused with the routine test on the production line; the type test is more severe.

  • Leakage current and earthing

    The current that could reach the user is measured; the continuity and resistance of the protective earthing path are verified.

  • Heating tests

    Temperatures of components, windings and accessible surfaces are measured in normal and abnormal operation.

  • Fault condition tests

    Components are deliberately short-circuited or open-circuited; the appliance is expected not to cause a fire and not to make a hazardous part accessible.

  • Mechanical and enclosure tests

    Impact, drop, strain relief, IP protection and the safety of moving parts are assessed.

Commonly confused in this field

  • A CB certificate is not a CE declaration. CB is the output of a mutual recognition arrangement that eases national certification; the CE declaration is made by the manufacturer under its own responsibility.
  • A part of IEC 60335 is not sufficient on its own; it is applied together with Part 1.
  • IEC 60950-1 and IEC 60065 have been withdrawn. Old certificates based on these codes cannot be used in a current file.
  • Separate certification of the adapter does not cover the conformity of the device; the device is assessed as the system it forms together with its power supply.
  • A change of critical component (transformer, fuse, optocoupler supplier) is not a silent change; it requires the safety file to be reviewed.

Which decisions these results support

  • CE declaration under the Low Voltage Directive
  • IECEE CB certificate and entry into national certification schemes
  • Assessing the safety impact of design changes
  • Establishing and maintaining the critical component list
  • Responding to market surveillance requests

Related Tests

Frequently Asked Questions About Short Circuit — IEC 60335

According to which standard is Short Circuit made?

Short Circuit is executed in scope IEC 60947-2, IEC 61439-1, IEC 60335-1, IEC 62133-2 (battery), IEC 60335, IEC 62368 and IEC 61010. The limit values ​​and acceptance criteria to be applied are defined in the product standard; The version valid for your product is confirmed in writing at the offer stage.

Which products does Short Circuit apply to?

Mainly applied to Electrical panels and distribution systems, Circuit breakers and fuses, Motor control centres, Battery systems and Power supplies. Whether your product is included in the scope is determined by examining its technical specifications and intended use.

Under what conditions is Short Circuit done?

The determining parameters are: Prospective short-circuit current — Defined in the installation or specification (in kA), Power factor — Defined in standard and Time — The protective element's breaking time. The full terms are in the "Test Conditions" section on the page and vary depending on the product standard.

What kind of sample is needed for Short Circuit?

The specimen must be in its real installation configuration, The protective element's type and rating must be documented and The prospective short-circuit current must be defined. The number of samples is determined according to the product standard and the scope to be reported.

How long does Short Circuit take?

The test duration is milliseconds; together with preparation and evaluation, several days. This duration belongs to the experiment itself; sample preparation, queuing and reporting are also evaluated. A realistic schedule for your product is given in the offer.

What is the Short Circuit result called "appropriate"?

The acceptance criterion is defined in the relevant standard: the protective element interrupting the current, preservation of enclosure integrity, and containment of arc emission.