What Is Ignitability?

Flammability test is performed in which the sample is exposed to a small flame source (EN ISO 11925-2) or defined heat flux (ISO 5657) for a defined period of time; It is the test in which ignition or flame spread is measured.

Purpose of Ignitability

The aim is to determine the material's resistance to small ignition sources and provide input into the response to fire classification.

Which Products Is Ignitability Applied To?

  • Building interior and exterior coatings
  • Insulation materials
  • Textiles and flooring
  • Plastic building elements

In Which Sectors Is Ignitability Used?

ConstructionConstructionDemiryoluElectricalConsumer Products

Standards Related to Ignitability

  • EN ISO 11925-2
  • ISO 5657
  • ASTM D1929 (ignition temperature)
  • EN 13501-1 (classification entry)
  • UL 94flammability class in plastic materials test
  • EN 13501Fire classification of building products test
  • ASTM E84flame spread on the surface test
  • ASTM E119Fire resistance in building elements test

Ignitability Conditions

Flame application
15 or 30 seconds in EN ISO 11925-2; surface and/or edge ignition
criterion
The flame reaches the defined marking line on the sample
Damlama
Burning drop formation is also recorded
Conditioning
In standard defined environment

Equipment for Ignitability

  • Small-flame ignitability chamber
  • Calibrated burner and timer
  • Ignition temperature furnace (ASTM D1929)
  • Conditioning room

Sample Requirements for Ignitability

  • Sample size and thickness must comply with the standard
  • Surface and edge ignition is done on separate samples
  • Conditioning must be completed
  • The number of specimens is defined in the standard

Duration of Ignitability

Typically 1–3 weeks.

Ignitability Procedure

  1. 1Samples are prepared and conditioned.
  2. 2Burner position and flame length are adjusted.
  3. 3Surface and edge ignition is applied.
  4. 4Flame progress and reaching the mark line are monitored.
  5. 5Burning drop formation is recorded.
  6. 6The results are compared with the classification criteria.

Ignitability Acceptance Criteria

The acceptance criteria are those defined in EN ISO 11925-2 and EN 13501-1: the flame does not reach the marking line and the drop criteria are met.

Evaluation of Results

Edge ignition is more challenging than surface ignition; If only the surface test is performed, the classification will be incomplete. Burning drop formation defines a separate subclass (d0/d1/d2) and must be recorded.

Ignitability Report

  • Standard applied
  • Specimen size and thickness
  • Flame application time and location
  • Flame progression and drop findings
  • Classification entry

Accreditation

EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.

Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.

Scope and authorisations

Related Regulations

  • Construction Products Directive (EU) 305/2011

Fire Testing — What Does This Testing Field Cover?

The section below describes the field that the Ignitability test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.

Fire testing measures two different concepts, and confusing them is the most common mistake in the field. REACTION to fire describes how much a material contributes to the start and growth of a fire. RESISTANCE to fire is the ability of a building element to hold a fire back for a defined period. One is a material property, the other a property of an element.

On the reaction side, ignitability, flame spread, heat release, smoke production, flaming droplets and toxic gas release are measured. The result is translated into an EN 13501-1 class in Europe, ASTM E84 indices in North America and a UL 94 class for appliance plastics. These three systems cannot be converted into one another; their scales and set-ups differ.

On the resistance side, furnace tests are carried out. The element is exposed to a defined temperature-time curve and it is measured how long it maintains three functions: load bearing (R), integrity (E) and insulation (I). For a fire door, the designation EI 60 says the element maintains its integrity and insulating function for sixty minutes.

SCALE is decisive in this family and directly affects cost. Small flame tests are suitable for screening materials and are fast and inexpensive. But real fire behaviour changes with scale: a material that self-extinguishes on a small specimen may sustain a flame over a large surface. Large-scale set-ups such as the room corner test and full-scale facade tests are therefore indispensable in critical applications.

Facade systems have become the most sensitive subject in the field in recent years. The rapid spread of facade fires in tall buildings has led national regulations to require large-scale facade testing. What is assessed here is not a single material but the SYSTEM: insulation, cladding, air cavity, fixings and fire barriers are tested together.

Smoke and toxicity form a separate body of work, because most deaths in a fire are caused by smoke rather than flame. In rail systems and on ships, smoke density and gas toxicity measurements are mandatory items; in an enclosed space the time available for evacuation depends on these values.

Cables have a sub-body of their own. A cable bundle inside a building can form a serious path for fire to spread between floors; flame spread, smoke production, halogen content and circuit integrity are therefore assessed for cables under separate standards, and in Europe the EN 13501-6 classification is used.

Method groups in this field

  • Non-combustibility and calorific value

    The EN ISO 1182 non-combustibility furnace and EN ISO 1716 gross calorific value; the determinants of classes A1 and A2.

  • Single burning item (SBI)

    EN 13823; heat release, flame spread and smoke production are measured together in a medium-scale corner set-up.

  • Small flame

    Ignitability with a single flame source to EN ISO 11925-2; UL 94 horizontal and vertical burning; needle flame and glow wire.

  • Cone calorimeter

    ISO 5660 / ASTM E1354; heat release rate, total heat release and smoke production are measured. The most informative test in material development.

  • Fire resistance

    Furnace tests with the standard temperature-time curve; separate set-ups for doors, walls, floors, glazing and service penetrations.

  • Large scale

    Room corner test (ISO 9705, NFPA 286), facade fire tests and vertical flame spread tests on cable bundles.

  • Smoke and toxicity

    Optical smoke density, smoke gas analysis and toxicity indices; mandatory in rail systems and marine.

Commonly confused in this field

  • Reaction to fire and resistance to fire are different concepts; the specification must be explicit about which is required.
  • UL 94, ASTM E84 and EN 13501-1 results cannot be converted into one another.
  • A small-scale result is not evidence of large-scale behaviour; large-scale testing is required in critical applications.
  • A class is valid together with the end-use installation of the product; a different substrate or air cavity changes the result.
  • For facade systems a result for a single material is not sufficient; the system must be tested as a whole.
  • The fire class of a product does not show the fire resistance of an assembly made from it.

Which decisions these results support

  • The fire class in the declaration of performance for construction products
  • Regulatory compliance in the selection of cables, flooring and interior linings
  • Approval of interior materials for rail vehicles, ships and aircraft
  • Approval of the facade system design
  • Meeting insurance and project specification requirements

Related Tests

Frequently Asked Questions About Ignitability

According to which standard is Ignitability made?

Ignitability is executed in scope EN ISO 11925-2, ISO 5657, ASTM D1929 (ignition temperature) and EN 13501-1 (classification entry). The limit values ​​and acceptance criteria to be applied are defined in the product standard; The version valid for your product is confirmed in writing at the offer stage.

Which products does Ignitability apply to?

Mainly applied to Building interior and exterior coatings, Insulation materials, Textiles and flooring and Plastic building elements. Whether your product is included in the scope is determined by examining its technical specifications and intended use.

Under what conditions is Ignitability done?

The determining parameters are: Flame application — 15 or 30 seconds in EN ISO 11925-2; surface and/or edge ignition, criterion — The flame reaches the defined marking line on the sample and Damlama — Burning drop formation is also recorded. The full terms are in the "Test Conditions" section on the page and vary depending on the product standard.

What kind of sample is needed for Ignitability?

Sample size and thickness must comply with the standard, Surface and edge ignition is done on separate samples and Conditioning must be completed. The number of samples is determined according to the product standard and the scope to be reported.

How long does Ignitability take?

Typically 1–3 weeks. This duration belongs to the experiment itself; sample preparation, queuing and reporting are also evaluated. A realistic schedule for your product is given in the offer.

What is the Ignitability result called "appropriate"?

The acceptance criteria are those defined in EN ISO 11925-2 and EN 13501-1: the flame does not reach the marking line and the drop criteria are met.