What Is Moisture?
Moisture determination is the measurement in which the water content in the sample is determined by Karl Fischer titration, mass loss (oven) or infrared drying methods.
Purpose of Moisture
The purpose is to verify that the moisture content of the polymer is below the permissible limit before processing; Moisture causes hydrolytic degradation and surface defects.
Which Products Is Moisture Applied To?
- Hygroscopic polymers such as polyamide, PET and PC
- Granule inspection before processing
- recycled polymers
- Fillers and additives
In Which Sectors Is Moisture Used?
Standards Related to Moisture
- ISO 15512
- ASTM D6980
- ASTM D789
- ISO 585
Moisture Conditions
- Method
- Karl Fischer titration, furnace mass loss or infrared/halogen drying
- Temperature
- Defined in the method; The temperature at which the polymer will not decompose is selected
- sample mass
- Defined in the method
- Specimen container
- Airtight; The sample must be preserved until measurement
Equipment for Moisture
- Karl Fischer titrator and furnace unit
- Halogen/infrared moisture analyzer
- Analytical balance
- Airtight sample containers
Sample Requirements for Moisture
- The sample must arrive in an airtight container and without exposure to ambient moisture.
- Must be measured quickly after sample collection
- The method should be chosen according to the polymer
- Blind measurement should be made
Duration of Moisture
Typically 1–2 days.
Moisture Procedure
- 1The sample is taken in an airtight container.
- 2Method and temperature are selected.
- 3Blind measurement is made.
- 4The sample is measured.
- 5Moisture content is calculated and reported.
Moisture Acceptance Criteria
The acceptance criterion is the maximum moisture content before processing in the material data sheet or specification.
Evaluation of Results
The mass loss method in the oven also counts volatile additives as moisture and gives high results; Karl Fischer is specific to water. The fact that the sample was exposed to air until it reached the laboratory invalidates the result.
Moisture Report
- Standard and method applied
- Temperature and sample mass
- Sample transport conditions
- Blind measurement result
- moisture content
Accreditation
EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.
Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.
Scope and authorisationsRelated Regulations
- Material data sheets and processing specifications
Food Testing — What Does This Testing Field Cover?
The section below describes the field that the Moisture test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.
Food testing shows that a product is safe for consumption and contains what its label states. The family works along three axes: microbiological safety, chemical safety and nutritional composition. All three require different laboratory infrastructure, a different body of methods and a different turnaround time.
The most distinctive feature of the field is TIME PRESSURE. A steel specimen can wait on a shelf; a raw milk or fresh meat sample cannot. The time the sample was taken, the transport temperature and how long it takes to reach the laboratory directly determine the validity of the result. In food microbiology the cold chain record is therefore an inseparable part of the test report.
On the microbiological side there are two different questions and they must not be confused. DETECTION of a pathogen is a qualitative question: is Salmonella present in the sample or not? ENUMERATION of indicator organisms is a quantitative question and an indicator of production hygiene. The absence of a pathogen in a product does not show that hygiene is good; if the total mesophilic aerobic count is high, there is a problem in the process.
On the chemical side, pesticide residues, mycotoxins, heavy metals, additives, veterinary drug residues and process contaminants (acrylamide, furan, PAH) are measured. Multi-residue methods in this area (QuEChERS-based LC-MS/MS and GC-MS/MS) can screen hundreds of active substances in a single analysis; limits are defined separately for each product–substance pair.
On the composition side, protein, fat, moisture, ash, fibre, sugar profile, fatty acid composition, vitamin and mineral content are determined. These values are the basis of the nutrition declaration on the label and the tolerance ranges are defined in legislation — the difference between the declared value and the measured value must stay within that tolerance.
There is NO CE marking on food, and this shapes how the field works. Conformity is demonstrated through operating a HACCP-based food safety system, complying with labelling rules and not exceeding contaminant, residue and microbiological limits. A test result produces evidence not for a certificate but for a functioning system.
Allergen management carries particular weight. The presence of an undeclared allergen in a product is one of the most frequent causes of food recalls. Analysis here runs together with cleaning validation: it is shown that the line has been cleaned adequately after a production run containing an allergen and that the risk of cross-contamination is under control.
Voluntary schemes have become effectively mandatory in this field. Retail chains require their suppliers to hold a certificate under a GFSI-recognised scheme (BRCGS, IFS, FSSC 22000); without it, getting onto the shelf is practically impossible.
Method groups in this field
Pathogen detection
Detection of Salmonella, Listeria monocytogenes, Campylobacter, Cronobacter and Shiga toxin-producing E. coli; culture-based and molecular methods.
Indicator counts
Total mesophilic aerobic count, Enterobacteriaceae, coliforms and E. coli, coagulase-positive staphylococci, yeasts and moulds, lactic acid bacteria, sulphite-reducing Clostridia.
Pesticide and veterinary residues
Multi-residue screening by LC-MS/MS and GC-MS/MS with QuEChERS extraction.
Mycotoxins and contaminants
Aflatoxins, ochratoxin A, deoxynivalenol, patulin; heavy metals (ICP-MS), acrylamide and PAH compounds.
Nutritional composition
Kjeldahl protein, fat and fatty acid profile, moisture, ash, dietary fibre, sugar profile, vitamin and mineral analyses.
Allergens and authenticity
Gluten, milk, egg, nut and soy allergen analyses; molecular methods for species identification and adulteration detection.
Commonly confused in this field
- Sampling is half the result. A sample transported at the wrong temperature or delayed gives an invalid result even if it is analysed correctly in the laboratory.
- The absence of a pathogen does not show that hygiene is good; indicator counts give separate information and the two are read together.
- A result from a sample taken from a lot can be generalised to the whole lot only if the sampling plan was set up statistically.
- Limits are defined in separate regulations by product group and are updated regularly; a conformity decision based on an outdated limit table may be wrong.
- For exports, the limits of the destination country may differ from EU limits; the same product may be compliant in one market and non-compliant in another.
Which decisions these results support
- Verification of the HACCP plan and process monitoring
- The basis for the nutrition declaration and allergen information on the label
- Health certificates before export and compliance with destination market limits
- Supplier and lot-based acceptance control
- Shelf-life studies and determining storage conditions
- Producing evidence for audits under GFSI-recognised schemes
Related Tests
Frequently Asked Questions About Moisture
According to which standard is Moisture made?
Moisture is executed in scope ISO 15512, ASTM D6980, ASTM D789 and ISO 585. The limit values and acceptance criteria to be applied are defined in the product standard; The version valid for your product is confirmed in writing at the offer stage.
Which products does Moisture apply to?
Mainly applied to Hygroscopic polymers such as polyamide, PET and PC, Granule inspection before processing, recycled polymers and Fillers and additives. Whether your product is included in the scope is determined by examining its technical specifications and intended use.
Under what conditions is Moisture done?
The determining parameters are: Method — Karl Fischer titration, furnace mass loss or infrared/halogen drying, Temperature — Defined in the method; The temperature at which the polymer will not decompose is selected and sample mass — Defined in the method. The full terms are in the "Test Conditions" section on the page and vary depending on the product standard.
What kind of sample is needed for Moisture?
The sample must arrive in an airtight container and without exposure to ambient moisture., Must be measured quickly after sample collection and The method should be chosen according to the polymer. The number of samples is determined according to the product standard and the scope to be reported.
How long does Moisture take?
Typically 1–2 days. This duration belongs to the experiment itself; sample preparation, queuing and reporting are also evaluated. A realistic schedule for your product is given in the offer.
What is the Moisture result called "appropriate"?
The acceptance criterion is the maximum moisture content before processing in the material data sheet or specification.