What Is Façade Watertightness?
In the watertightness test, water is sprayed evenly onto the exterior surface of a facade or window sample while the pressure differential is stepped up on the interior side. At each pressure step it is observed whether water passes to the interior surface. The watertightness class is determined by the highest pressure step reached without leakage observed.
Purpose of Façade Watertightness
The purpose is to show that the facade does not admit water under the combined effect of rain and wind. Facade leaks are among the most expensive post-construction remediation items; the test is therefore usually required on a prototype before manufacturing.
Which Products Is Façade Watertightness Applied To?
- Curtain wall systems
- Window and door systems
- Glass roofs and skylights
- Panel facade systems
In Which Sectors Is Façade Watertightness Used?
Standards Related to Façade Watertightness
- EN 12155 (curtain walling — watertightness, laboratory test under static pressure)
- EN 1027 (windows and doors — watertightness test)
- EN 13051 (curtain walling — watertightness, site test)
- EN 12154 / EN 12208 (watertightness classification)
Façade Watertightness Conditions
- Method
- Static or dynamic pressure in the laboratory; EN 13051 in the field
- Su debisi
- Spray flow rate and nozzle arrangement defined in the standard
- Pressure levels
- Starting from zero and increasing in steps defined in the standard
- Time
- Standard-defined waiting time at each level
Equipment for Façade Watertightness
- Facade test wall and pressure chamber
- Calibrated water spray nozzle array and flow meter
- Pressure generation and measurement system
- Interior surface observation setup and recording system
Sample Requirements for Façade Watertightness
- The sample must be taken so as to represent the batch and in accordance with the sampling rules of the relevant standard.
- The sampling date, location and the person who took the sample must be recorded.
- Samples requiring curing or conditioning must be stored under the defined conditions.
- The number of samples must meet the minimum required by the standard.
- The sample must not be damaged during transport.
Duration of Façade Watertightness
Mounting the sample on the test wall often takes longer than the test itself. Mounting and testing together generally take a few days.
Façade Watertightness Procedure
- 1The sample is mounted on the test wall with its project details.
- 2An air permeability test (if applicable) is done first.
- 3The water spray system is set up and flow rate verified.
- 4While water is sprayed, the pressure differential is started from zero.
- 5Pressure is increased in the defined steps, dwelling at each.
- 6Water passage on the interior surface is continuously observed.
- 7The step at which leakage is observed is recorded and the class determined.
Façade Watertightness Acceptance Criteria
The acceptance class does not come from the test method but from the product standard and the project: concrete class, reinforcement class, aggregate category, or fire performance class is defined in the specification. The report gives the measured value; the conformity decision is made against the relevant product standard.
Evaluation of Results
The result is classified by the highest pressure step completed without leakage observed. Which class is required is determined by the building's height, location and wind load calculation; this value comes from the project.
Façade Watertightness Report
- Sample description, sampling location and date
- Sampling method and witness sample information, if any
- Standard and test conditions applied
- Sample dimensions, curing conditions and age information
- Measured values and calculated results
- Failure mode or damage description (where applicable)
- A statement that the result applies only to the specimen submitted for testing
Accreditation
EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.
Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.
Scope and authorisationsRelated Regulations
- EU 305/2011 Construction Products Regulation (CPR)
- Construction Products Regulation (Turkey)
- TS 500 / Requirements for Design and Construction of Reinforced Concrete Structures
- Turkish Building Earthquake Code
Construction Materials Testing — What Does This Testing Field Cover?
The section below describes the field that the Façade Watertightness test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.
Construction materials testing shows whether a product performs the function it takes on within the structure. A wide field is gathered in this family, from the compressive strength of concrete to the thermal transmittance of glass, from sieve analysis of aggregate to the watertightness of windows.
What sets this family apart from the others is that the result turns directly into a REGULATORY DECLARATION. For products covered by construction products legislation a declaration of performance (DoP) is mandatory, and every essential characteristic in the declaration rests on a test result. Reaction-to-fire class, thermal conductivity, compressive strength, water permeability and release of dangerous substances are declared in this way. The declaration is a legal text carrying the manufacturer's signature; the test record behind it is the first document requested in an inspection.
The second distinguishing feature is that the product is assessed over its SERVICE LIFE. An electronic device runs for five years; a building component stays in place for fifty and is exposed throughout that time to freeze-thaw cycles, UV, moisture, chemical attack and load. Durability tests (freeze-thaw, carbonation, alkali-silica reaction, ageing) therefore carry as much weight in this field as classical strength tests.
Tests are separated by material type and each group has its own set of standards: cement and concrete, aggregate, masonry units, wood-based panels, thermal insulation, glass and glazing units, ceramic tiles, floor coverings, screeds, joint fillers and coating systems. Where the product will be installed determines which set applies — the same panel is assessed against different standards on a wall and on a floor.
Factory production control (FPC) is a continuous component of the field. CE marking on a construction product is not obtained with a single test and then left; the manufacturer must set up a system showing that it monitors production consistency, takes samples regularly and intervenes when there is a deviation. Depending on the product group, this system may have to be audited by a notified body.
Site testing is a separate body of work. In the laboratory the product is approved; on site it is checked that the product really is of the declared class and that it has been applied correctly. Fresh concrete slump, cylinder sampling, aggregate sieve analysis and in-situ watertightness tests fall within this scope.
Method groups in this field
Concrete and cement
Slump, air content and unit weight in fresh concrete; compressive and flexural strength, water permeability and freeze-thaw resistance in hardened concrete. For cement, compressive strength, setting time and composition analysis.
Aggregate
Sieve analysis, particle shape, Los Angeles abrasion resistance, freeze-thaw, alkali reactivity and density/water absorption.
Thermal and energy performance
Thermal conductivity and thermal resistance, calculation of thermal transmittance (U value) in glazing units, solar energy transmittance.
Facade and joinery
Air permeability, watertightness and wind load resistance in windows and doors; fire performance in facade systems.
Fire performance
Reaction-to-fire classification and fire resistance tests; these are two separate concepts and are addressed by separate standards.
Masonry, tile and flooring
Compressive strength, water absorption, abrasion resistance, slip resistance, stain and chemical resistance.
Emissions and dangerous substances
Formaldehyde release from wood-based panels, VOC emissions from construction products, leaching behaviour of aggregates and waste.
Commonly confused in this field
- REACTION to fire and RESISTANCE to fire are different concepts: one describes the material's contribution to a fire, the other how long a component holds the fire back.
- A declaration of performance is not a certificate; it is the manufacturer's declaration. Notified body involvement varies with the product group and the assessment system.
- A test result is valid for the mounting arrangement in which the product was tested. A different substrate, a different thickness or a different joint detail may require reassessment.
- A site sample and a laboratory sample are not the same thing. A concrete cylinder taken on site also reflects application and curing conditions; it does not replace product approval.
- ASTM and EN construction standards measure similar quantities with different specimens and scales; the results cannot be converted one-to-one.
Which decisions these results support
- Declaration of performance (DoP) and CE marking
- Establishing and maintaining the factory production control system
- On-site conformity control of concrete, aggregate and workmanship
- Meeting fire and energy performance requirements
- Verifying the technical items in the project and tender specification
Related Tests
Frequently Asked Questions About Façade Watertightness
What is the definition of leakage?
The standard considers a continuous film of water forming on the interior surface, or dripping, as leakage. Moisture from condensation is assessed separately from this.
Does the site test replace the laboratory test?
No. The EN 13051 site test checks installation quality and does not give a classification; classification is done on a prototype in the laboratory.