Acute Systemic Toxicity

ISO 10993-11ISO 10993-1ISO 10993-12USP <88>ISO 11607
Medikal Cihaz Testleri laboratory work

What Is Acute Systemic Toxicity?

The acute systemic toxicity test evaluates whether the device extract causes a body-wide toxic effect after a single application. Unlike local effects, it concerns the effect on organs of substances that enter circulation.

Purpose of Acute Systemic Toxicity

The purpose is to determine whether substances released from devices in contact with blood or circulation carry a systemic toxic risk.

Which Products Is Acute Systemic Toxicity Applied To?

  • Blood sets and dialysis equipment
  • Intravenous catheters and infusion sets
  • Implants
  • Surgical devices
  • Heart-lung machine components

In Which Sectors Is Acute Systemic Toxicity Used?

Medical DeviceHealthcarePharmaceuticals

Standards Related to Acute Systemic Toxicity

  • ISO 10993-11sistemik toksisite test
  • ISO 10993-1
  • ISO 10993-12
  • USP <88>
  • ISO 11607end product sterile barrier packaging test

Acute Systemic Toxicity Conditions

Extraction
With polar and non-polar solvents; per ISO 10993-12 ratios
Route of administration
Chosen to match the device's clinical route of use
Observation
Clinical signs and body weight are monitored for a defined period after administration

Equipment for Acute Systemic Toxicity

  • Extraction rig and incubator
  • Animal housing and care infrastructure
  • Clinical observation and weighing equipment
  • Pathology infrastructure (if required)

Sample Requirements for Acute Systemic Toxicity

  • The specimen must represent the final, sterilised product
  • Not raw material — the product that has gone through all manufacturing and sterilisation processes is submitted
  • The specimen quantity is determined according to the surface-area/extraction ratio prescribed by the standard
  • The device's type and duration of body contact must be stated
  • The sterilisation method and, if applicable, residue information must be shared

Duration of Acute Systemic Toxicity

Typically several weeks, together with extraction, administration and observation periods.

Acute Systemic Toxicity Procedure

  1. 1The device's contact type is assessed to justify the need for the test.
  2. 2The specimen is extracted with polar and non-polar solvents.
  3. 3The extract is administered as a single dose by the appropriate route.
  4. 4The solvent is administered to the control group.
  5. 5Clinical signs and body weight are monitored throughout the defined observation period.
  6. 6An assessment is made at the end of the observation period.
  7. 7Results are compared with the control group.

Acute Systemic Toxicity Acceptance Criteria

The acceptance criterion is that the test group shows no significant toxic finding (clinical sign, weight loss, death) relative to the control group. Thresholds are defined in the standard's text.

Evaluation of Results

Findings are interpreted comparatively against the control group. If a positive finding occurs, chemical characterisation (ISO 10993-18) is used to identify the responsible substance in the extract.

Acute Systemic Toxicity Report

  • Applied standard and revision
  • Specimen description, batch number and sterilisation method
  • Extraction conditions (solvent, temperature, duration, ratio)
  • Positive and negative control results
  • Test results and grading
  • Assessment and conclusion

Accreditation

EUROLAB holds internationally recognised accreditation obtained from accreditation bodies party to the IAF and ILAC multilateral recognition arrangements, under ISO/IEC 17025 for laboratory testing, ISO/IEC 17020 for inspection and surveillance, and ISO/IEC 17021-1 and ISO/IEC 17065 for system and product certification. This chain ensures the reports and certificates issued are accepted worldwide.

Whether this test can be offered within accredited scope depends on your product and the standard applied; since accreditation is method-based, the scope is confirmed in writing at the quotation stage.

Scope and authorisations

Related Regulations

  • MDR (EU) 2017/745
  • Ethical and legal regulations on animal testing

Medikal Cihaz Testleri — What Does This Testing Field Cover?

The section below describes the field that the Acute Systemic Toxicity test belongs to; the conditions and acceptance criteria of this particular test are given in the sections above. The scope specific to your product is confirmed in writing at the quotation stage.

Medical device testing shows that a device is safe for the patient and the user and maintains its intended performance. In this family safety is not only about avoiding harm; a device failing to perform its expected function is also treated as a risk. A monitor missing an alarm or a pump delivering the wrong dose is directly a patient safety event.

At the centre of the field is RISK MANAGEMENT, and this is what sets medical apart from other sectors. The risk management process run under ISO 14971 also determines which tests are required. The test list is not copied from a table of standards; it is derived and justified from the device's intended use, the nature and duration of patient contact, the use environment and foreseeable misuse.

Assessment consists of several separate bodies of work, each with its own set of standards. Biocompatibility runs through the ISO 10993 series, electrical device safety through the IEC 60601 series, sterilisation through ISO 11135/11137/17665, packaging through ISO 11607, software through IEC 62304 and usability through IEC 62366. The quality system (ISO 13485) is the framework that binds these together.

Which tests are required is determined by the device's CLASS and its MODE OF CONTACT WITH THE BODY. A product in brief contact with skin and an implant entering the bloodstream do not go through the same test set; the scope is set by a biological evaluation plan prepared under ISO 10993-1. That plan justifies in writing which endpoints are required and why the others are not.

Packaging and sterilisation are taken as seriously as the device itself in this field. For a sterile device the packaging is not a transport container but the barrier that maintains sterility; if the barrier is breached, the device is no longer sterile. Packaging processes are therefore validated and shelf life is supported by real-time ageing data.

For devices containing software, assessment shifts from testing towards PROCESS assurance. IEC 62304 defines which development and verification steps must be followed according to the safety class of the software; the evidence is the traceability of the development process. Testing software does not make it safe — the process record does.

The clinical side is a separate column of the technical file. Test reports show that the device is technically safe; clinical evaluation establishes that the device delivers the intended clinical benefit and that the benefit-risk balance is acceptable. Neither replaces the other.

Method groups in this field

  • Biocompatibility

    Cytotoxicity, irritation, skin sensitisation, systemic toxicity, haemocompatibility, genotoxicity and local effects after implantation. The required endpoints are set by the ISO 10993-1 plan.

  • Electrical device safety

    IEC 60601-1 basic safety and essential performance; EMC, alarm, usability and environmental requirements through the collateral standards.

  • Sterilisation validation

    Validation of sterilisation processes by ethylene oxide, radiation or moist heat; bioburden and sterility assurance level studies.

  • Packaging

    Integrity of the sterile barrier system, seal strength, distribution simulation and shelf-life studies.

  • Microbiological tests

    Bioburden determination, sterility testing, bacterial endotoxin and, where required, carrier validation studies.

  • Software and usability

    IEC 62304 life cycle evidence and use-error focused evaluation under IEC 62366.

Commonly confused in this field

  • Cytotoxicity alone is not evidence of biocompatibility; the required set of endpoints is determined and justified according to ISO 10993-1.
  • An ISO 13485 certificate does not confer CE marking; classification under the MDR, the technical file and the notified body process run separately.
  • Accelerated ageing does not replace real-time ageing; a shelf life claim is supported by real-time data.
  • A change of material (supplier, pigment, sterilisation method) may require the biological evaluation to be repeated; it is not a silent change.
  • An assessment made without the collateral and particular standards for IEC 60601-1 is incomplete; which -1-x and -2-x standards were applied must appear in the report.
  • In vitro diagnostic devices fall under the IVDR rather than the MDR, and laboratory equipment is often on the IEC 61010-1 side.

Which decisions these results support

  • MDR/IVDR technical file and notified body assessment
  • Completing the biological evaluation plan
  • Sterilisation and packaging validation
  • Determining shelf life and storage conditions
  • Determining the scope of reassessment after a design change

Related Tests

Frequently Asked Questions About Acute Systemic Toxicity

Is this test required for every device?

No. ISO 10993-1 requires test selection according to contact type and duration; acute systemic toxicity mainly arises for devices in contact with blood and circulation. Also, chemical characterisation and toxicological risk assessment can, in some cases, substitute for the test.

We use cookies required for the site to work. With your permission we also add an analytics cookie to understand how pages are used. Cookie Policy